The company is a professional modern enterprise in the production, research and development and sales of high-tech products for wires and cables. Main production: overhead insulated wires, special cables, steel core aluminum stranded wires, aluminum stranded wires, cable reels; Cold-drawn aluminum wire and other wires and cables. Our company has a complete and scientific quality management system.

Parameter,Description
Nominal Cross - Section Area of Aluminum Strand,Expressed in square millimeters (
), representing the total cross - sectional area of the aluminum strands in the conductor. Common sizes include 10
, 25
, 50
, 70
, 95
, 120
, 150
, 185
, 240
, 300
, 400
, 500
, etc.
Nominal Cross - Section Area of Steel Core,Also in square millimeters (
), indicating the cross - sectional area of the steel core inside the conductor. Sizes vary according to different models, such as 1
, 4
, 7
, 10
, 16
, 20
, 25
, etc.
Number of Aluminum Strands,Refers to the quantity of individual aluminum strands in the conductor. It could be 7, 12, 18, 24, 30, 37, etc.
Number of Steel Strands,The number of steel strands within the steel core, which may be 1, 7, 19, etc.
Diameter of Aluminum Strand,Measured in millimeters (mm), representing the diameter of each single aluminum strand. Typical values range from 1.0 mm to 3.0 mm depending on the overall design of the conductor.
Diameter of Steel Strand,Expressed in millimeters (mm), denoting the diameter of each steel strand. Usually, it is in the range of 1.0 mm to 2.5 mm.
Overall Diameter of the Conductor,The outer diameter of the entire steel - core aluminum stranded wire, measured in millimeters (mm). It is determined by the combination of the number and diameters of the aluminum and steel strands. For example, it may be 5.0 mm, 8.0 mm, 10.0 mm, 12.0 mm, 15.0 mm, etc.
DC Resistance per Unit Length at 20°C,Measured in ohms per kilometer (
/km). This value indicates the resistance of the conductor to direct current at a temperature of 20 degrees Celsius. The resistance value decreases as the cross - sectional area of the aluminum strand increases. For example, for a 10
aluminum - conductor steel - reinforced wire, the DC resistance per unit length may be around 3.12
/km, while for a 400
one, it may be approximately 0.073
/km.
Rated Tensile Strength,Expressed in newtons (N), representing the maximum tensile force that the conductor can withstand without breaking. It is related to the cross - sectional area and mechanical properties of the steel core and aluminum strands. Higher - strength conductors are used in applications where greater mechanical stress is expected. For example, some conductors may have a rated tensile strength of 10000 N, 20000 N, 30000 N, etc.
Weight per Unit Length,Measured in kilograms per kilometer (kg/km), which is affected by the cross - sectional area and material density of both the aluminum and steel parts. Heavier conductors are generally used for shorter - span applications, while lighter ones are more suitable for longer - span installations. For example, a 10
conductor may weigh around 42 kg/km, and a 400
conductor may weigh approximately 1500 kg/km.
Q1: Are you manufacture?
A: YES we are manufacturer.
Q2: Do you provide free sample?
A: YES, we supply you free sample within one day.
Q3: What is your deivery time?
A: Our delivery time is normally 7 to 15 days after deposit.
Q4: May I visit your factory?
A: Yes we welcome your visiting us someday at your convenience.
Q5: Can you accept our deisgn and products?
A: Yes we have professional engineer teams. We can deisgn and produce special products